Laboratory equipment manufacturer & supplier in Chennai
SterilizationVertical Autoclave - Without Control System laboratory equipment by Hasthas Scientific Instruments Chennai
Representative product image. Final appearance may vary by model, size and configuration.
Sterilization Equipment
Model: HSI-101

Vertical Autoclave - Without Control System

Manual Vertical Autoclave from Hasthas Scientific Instruments, Chennai, for operator-managed laboratory steam processing. Steam supplies moist heat while the vessel contains pressure. In an operator-managed configuration, staff follow the specified operating sequence and observe the instruments throughout the process. This model name should not be interpreted as an absence of required pressure-relief or other safety fittings. #ManualVerticalAutoclave #ManualVerticalAutoclaveChennai #ManualVerticalAutoclaveManufacturer #ManualVerticalAutoclaveSupplier #LaboratorySterilizer #SteamSterilizer #LaboratoryEquipment #ScientificInstruments #Chennai #TamilNadu #HasthasScientific #VerticalAutoclaveWithoutControlSystem #LabEquipmentChennai

Indicative price: ₹36,500Demo estimate. Final price depends on model, capacity, accessories, quantity and delivery requirements.
Maximum pressure: 30 psiWorking pressure: 15 psi22-187 L listed sizes
Need a different capacity?Share your required size, application and quantity.
Call +91 93612 32452
Product Note

Autoclave Manufacturer in Chennai | Hasthas Scientific Instruments Hasthas Scientific Instruments is a leading autoclave manufacturer and laboratory equipment supplier in Chennai, Tamil Nadu, offering high-quality laboratory autoclaves for efficient sterilization of laboratory glassware, instruments, media and other heat-resistant materials. Our laboratory autoclaves are designed for reliable steam sterilization, consistent temperature control and safe operation in research laboratories, hospitals, colleges, universities, pharmaceutical industries, microbiology laboratories and testing facilities. We manufacture and supply vertical autoclaves, horizontal autoclaves and laboratory steam sterilizers in different capacities and configurations to meet diverse laboratory requirements. Our autoclaves are built with durable materials and safety features for dependable long-term performance. If you are looking for an autoclave manufacturer in Chennai, autoclave supplier in Tamil Nadu, laboratory autoclave manufacturer in India or steam sterilizer supplier, Hasthas Scientific Instruments provides reliable laboratory sterilization equipment with manufacturer support. Source a manual vertical autoclave from Hasthas, Chennai. Review 15 psi working pressure, 22–187 L sizes and standard controls; request a price quotation. #ManualVerticalAutoclave #ManualVerticalAutoclaveChennai #ManualVerticalAutoclaveManufacturer #ManualVerticalAutoclaveSupplier #LaboratorySterilizer #SteamSterilizer #LaboratoryEquipment #ScientificInstruments #Chennai #TamilNadu #HasthasScientific #VerticalAutoclaveWithoutControlSystem #LabEquipmentChennai

Technical details and application

Review the available information and contact Hasthas to confirm the final model and commercial quotation.

Construction

Double-walled construction with stainless-steel boiler, inner chamber, outer chamber and thick stainless-steel lid with wing-nut locking.

Pressure and safety

Maximum pressure 30 psi; regular working pressure 15 psi; spring-loaded safety valve adjustable from 15 to 20 psi (+/- 3 psi); hydraulically tested up to 40 psi.

Heating and fittings

ISI-marked immersion heating element, pressure gauge, steam-release cock, safety valve and drain outlet.

Included supply

Pedal lifting device, perforated stainless-steel basket, wing-nut opener, cord and plug.

Electrical supply

220 V, 50 Hz AC.

Available chamber sizes

Select a suitable capacity based on your application, laboratory space and daily workload.

Inner chamber dia. x depthCapacityLoad
250 x 450 mm22 L2.0 kW
300 x 500 mm40 L3 kW
350 x 600 mm50 L3 kW
450 x 600 mm90 L4 kW
550 x 750 mm187 L5 kW
750 x 1000 mmNot stated6.5 kW

Available additions and configurations

Optional items may depend on the selected size and model. Confirm availability while requesting your quotation.

  • Water-level indicator
  • Automatic low-water cut-off switch
  • Automatic pressure-control cut-off switch
  • Digital temperature controller-cum-indicator with sensor
  • Digital timer
  • Radial locking system

Vertical Autoclave - Without Control System manufacturer and supplier in Chennai

Manual Vertical Autoclave from Hasthas Scientific Instruments, Chennai, for operator-managed laboratory steam processing. Steam supplies moist heat while the vessel contains pressure. In an operator-managed configuration, staff follow the specified operating sequence and observe the instruments throughout the process. This model name should not be interpreted as an absence of required pressure-relief or other safety fittings. #ManualVerticalAutoclave #ManualVerticalAutoclaveChennai #ManualVerticalAutoclaveManufacturer #ManualVerticalAutoclaveSupplier #LaboratorySterilizer #SteamSterilizer #LaboratoryEquipment #ScientificInstruments #Chennai #TamilNadu #HasthasScientific #VerticalAutoclaveWithoutControlSystem #LabEquipmentChennai

Source a manual vertical autoclave from Hasthas, Chennai. Review 15 psi working pressure, 22–187 L sizes and standard controls; request a price quotation.

01

Common applications

Manual Vertical Autoclave from Hasthas Scientific Instruments, Chennai, for operator-managed laboratory steam processing. Steam supplies moist heat while the vessel contains pressure. In an operator-managed configuration, staff follow the specified operating sequence and observe the instruments throughout the process. This model name should not be interpreted as an absence of required pressure-relief or other safety fittings. #ManualVerticalAutoclave #ManualVerticalAutoclaveChennai #ManualVerticalAutoclaveManufacturer #ManualVerticalAutoclaveSupplier #LaboratorySterilizer #SteamSterilizer #LaboratoryEquipment #ScientificInstruments #Chennai #TamilNadu #HasthasScientific #VerticalAutoclaveWithoutControlSystem #LabEquipmentChennai

02

Selection points

The standard vertical configuration suits enquiries where electronic control is not requested. Review operator procedures, steam-load compatibility and the supplied safety fittings before selecting a chamber. Listed highlights: Maximum pressure: 30 psi; Working pressure: 15 psi; 22-187 L listed sizes.

03

Sizes and options

Available chamber sizes: 250 x 450 mm / 22 L / 2.0 kW; 300 x 500 mm / 40 L / 3 kW; 350 x 600 mm / 50 L / 3 kW; 450 x 600 mm / 90 L / 4 kW; 550 x 750 mm / 187 L / 5 kW; 750 x 1000 mm / Not stated / 6.5 kW. Confirm the selected configuration and options when requesting a quotation.

Buy Vertical Autoclave - Without Control System from Hasthas in Chennai

Hasthas Scientific Instruments manufactures and supplies Vertical Autoclave - Without Control System in Chennai, Tamil Nadu. The standard vertical configuration suits enquiries where electronic control is not requested. Review operator procedures, steam-load compatibility and the supplied safety fittings before selecting a chamber. Share quantity and delivery requirements for a current price quotation in India.

Manual Vertical Autoclave: operation and selection

Working principle

Steam supplies moist heat while the vessel contains pressure. In an operator-managed configuration, staff follow the specified operating sequence and observe the instruments throughout the process. This model name should not be interpreted as an absence of required pressure-relief or other safety fittings.

Choosing a configuration for operator-managed laboratory steam processing

The standard vertical configuration suits enquiries where electronic control is not requested. Review operator procedures, steam-load compatibility and the supplied safety fittings before selecting a chamber.

What should a laboratory compare with the controller version?

Compare operator responsibilities, monitoring arrangements, pressure-control options and the exact supplied fittings. Choose around the laboratory’s approved workflow and available trained staff, rather than assuming two visually similar units perform identical cycles.

Use and maintenance planning

Record checks and cycle observations in the laboratory log. Follow the manual for water quality, cleaning, cool-down and inspection of seals and valves. Arrange servicing when a gauge, seal or control behaves unexpectedly.

Discuss your requirement with Hasthas

Contact our Chennai team with the intended procedure, sample or vessel dimensions, quantity and installation requirements. We can review the listed configurations with you and identify the details that need confirmation in your quotation.

Request Manual Vertical Autoclave details

Related guides

What Is a Vertical Autoclave Without Controller? Uses and Applications

Related products

Questions about Vertical Autoclave - Without Control System

Use these answers to prepare a clearer technical and commercial enquiry.

What should a laboratory compare with the controller version?

Compare operator responsibilities, monitoring arrangements, pressure-control options and the exact supplied fittings. Choose around the laboratory’s approved workflow and available trained staff, rather than assuming two visually similar units perform identical cycles.

How can I request a manual vertical autoclave quotation in Chennai?

The standard vertical configuration suits enquiries where electronic control is not requested. Review operator procedures, steam-load compatibility and the supplied safety fittings before selecting a chamber. Share the quantity, installation address and requested delivery date with Hasthas. Current availability and the final price are confirmed in the quotation.

What is Vertical Autoclave - Without Control System used for?

Manual Vertical Autoclave from Hasthas Scientific Instruments, Chennai, for operator-managed laboratory steam processing. Steam supplies moist heat while the vessel contains pressure. In an operator-managed configuration, staff follow the specified operating sequence and observe the instruments throughout the process. This model name should not be interpreted as an absence of required pressure-relief or other safety fittings. #ManualVerticalAutoclave #ManualVerticalAutoclaveChennai #ManualVerticalAutoclaveManufacturer #ManualVerticalAutoclaveSupplier #LaboratorySterilizer #SteamSterilizer #LaboratoryEquipment #ScientificInstruments #Chennai #TamilNadu #HasthasScientific #VerticalAutoclaveWithoutControlSystem #LabEquipmentChennai

Which Vertical Autoclave - Without Control System specifications should I review?

Review Maximum pressure: 30 psi; Working pressure: 15 psi; 22-187 L listed sizes. Confirm suitability for your procedure and the exact configuration before ordering.

What is the price of Vertical Autoclave - Without Control System?

Indicative price: ₹36,500. This is a temporary demo estimate. Final price depends on model, capacity, accessories, quantity and delivery requirements. Request a current quotation from Hasthas Scientific Instruments, Chennai.

Need equipment for your laboratory?

Share the product, capacity and quantity. Our team will help with suitable options.

CallWhatsApp